{"id":209,"date":"2016-11-28T10:59:26","date_gmt":"2016-11-28T10:59:26","guid":{"rendered":"http:\/\/wp.gekakonus.net\/?page_id=209"},"modified":"2017-04-20T08:13:16","modified_gmt":"2017-04-20T08:13:16","slug":"hochdruckdampferzeuger-im-offenen-dampfkondensatkreislauf","status":"publish","type":"page","link":"https:\/\/gekakonus.net\/en\/produkte\/hochdruckdampferzeuger-im-offenen-dampfkondensatkreislauf\/","title":{"rendered":"High Pressure Steam Boiler in open steam\/condensate cycle"},"content":{"rendered":"<p><\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"size-full wp-image-211 aligncenter\" src=\"https:\/\/wp.gekakonus.net\/wp-content\/uploads\/2016\/11\/NWK-HP.jpg\" alt=\"nwk-hp\" width=\"500\" height=\"310\" srcset=\"https:\/\/gekakonus.net\/wp-content\/uploads\/2016\/11\/NWK-HP.jpg 500w, https:\/\/gekakonus.net\/wp-content\/uploads\/2016\/11\/NWK-HP-300x186.jpg 300w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p>\n<h1>The basis for the High Pressure Steam Boiler in open steam\/condensate cycle<\/h1>\n<p>The basis for the GekaKonus\u00ae High Pressure Steam Boiler in open steam\/condensate cycle type NWK-HP\u00a0system is a modified GekaKonus\u00ae Natural Circulation Steam Boiler type NUK-HP\u00ae combined with a steam drum. The GekaKonus\u00ae NWK-HP\u00a0system is being used in heating processes where the implementation of a closed steam\/condensate cycle system is not possible.<\/p>\n<div>\n<h2>\u00a0<\/h2>\n<table class=\" alignleft\" style=\"border-color: #fa0202; background-color: #fc0303;\">\n<thead>\n<tr style=\"background-color: #f70505;\">\n<td><span style=\"font-family: arial,helvetica,sans-serif; font-size: 20px;\"><strong>Application\/Advantages<br \/>\n <\/strong><\/span><\/td>\n<\/tr>\n<\/thead>\n<\/table>\n<p>Application<br \/>\n The GekaKonus\u00ae NWK-HP\u00a0system is being used in heating processes where it is necessary to work with different steam pressures at different stages in the production process within the same system e.g. with different saturated steam temperature or in processes where the condensate can&#8217;t flow directed back into the feed water system.<br \/>\n The GekaKonus\u00ae High Pressure Steam Boiler in open steam\/condensate cycle type NWK-HP\u00a0system can be used for the thermal high-pressure-splitting process of fats and oils for the production of fatty acid and glycerine water.<\/p>\n<p>Advantages<br \/>\n The release of changing time steam mass flows in adequate time intervals guarantees a constant steam pressure in the steam drum.<br \/>\n The released saturated steam is dry.<br \/>\n Boiler water should not be able to escape if the released steam mass flow does not exceed the capacity of the GekaKonus\u00ae NWK-HP.<br \/>\n A wide capacity control range depending on the type of burner can be offered.<\/p>\n<p>We are also able to offer customized capacity ranges.<\/p>\n<p>You find further technical information on every type of heater in the download area of our internet site.<\/p>\n<\/div>\n<table style=\"border-color: #f50521; background-color: #fa0522;\">\n<tbody>\n<tr>\n<td><strong><span style=\"font-family: arial,helvetica,sans-serif; font-size: 20px;\">Production\/Equipment<\/span><\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<article class=\"accordion-lang380px\"><\/article>\n<article>\n<p>Production<br \/>\n Equipped and produced in conformity with the European Community technical rules (PED 2014\/68\/ EU), and other world-wide acceptance organisations (e.g. SELO, GOST-R, RTN, ASME, AS).<\/p>\n<p>Equipment<br \/>\n The boiler equipment is for operation without supervision (acc. PED and EN 12952).<\/p>\n<p>Capacity Control<br \/>\n The output capacity is controlled by pressure. The steam pressure measured in the steam drum gives the signal for the burner. Depending on the change in steam pressure the capacity of the burner is increased or reduced.<\/p>\n<h3>Burner<\/h3>\n<p>The NWK-HP\u00ae can be equipped with burners for light oil, heavy oil, bio diesel, natural gas, liquid gas, biogas, or with two-component burners. The choice of burner depends upon the boiler capacity, the fuel and the demands expected of capacity control.<br \/>\n The capacity can be controlled by modulating controlling.<\/p>\n<p>A permanent supervision of the following parameters:<\/p>\n<ul type=\"disc\">\n<li>Stream Pressure &#8211; Operating<\/li>\n<li>Stream Pressure &#8211; Maximum<\/li>\n<li>Boiler Water &#8211; Normal Level<\/li>\n<li>Boiler Water &#8211; Minimum Level<\/li>\n<li>Boiler Water &#8211; Maximum Level<\/li>\n<li>Exhaust Gas Temperature<\/li>\n<li>Boiler Water &#8211; Density<\/li>\n<li>Boiler Water &#8211; Blow Down<\/li>\n<\/ul>\n<p>You find further technical information on every type of boiler in the download area of our internet site.<\/p>\n<\/article>\n<table style=\"border-color: #fa0000; background-color: #fa0000;\">\n<tbody>\n<tr>\n<td><strong><span style=\"font-family: arial,helvetica,sans-serif; font-size: 20px;\">Technical Data<\/span><\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div>\n<p>Capacity Range:<\/p>\n<p>Operating pressure: 30 &#8211; 90 bar<br \/>\n Saturated steam output: up to 24.000 kg\/h<\/p>\n<p>You find further technical information on every type of boiler in the download area of our internet site.<\/p>\n<\/div>\n<div>\u00a0<\/div>\n<table style=\"border-color: #fa0000; background-color: #fa0000;\">\n<tbody>\n<tr>\n<td><strong><span style=\"font-family: arial,helvetica,sans-serif; font-size: 20px;\">P+I Diagram\/Schema<\/span><\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div>\n<article class=\"accordion-lang260px\"><span style=\"font-family: arial,helvetica,sans-serif;\"><a href=\"https:\/\/wp.gekakonus.net\/wp-content\/uploads\/2016\/11\/diagramm_nwk1g.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"wp-image-214 size-thumbnail alignleft\" src=\"https:\/\/wp.gekakonus.net\/wp-content\/uploads\/2016\/11\/diagramm_nwk1g-150x150.jpg\" width=\"150\" height=\"150\" \/><\/a><br \/>\n <\/span><\/article>\n<\/div>\n<article class=\"accordion-lang260px\">\n<table style=\"width: 708.08px;\">\n<tbody>\n<tr>\n<td style=\"width: 697.08px;\">\n<article class=\"accordion-lang260px\">1. Steam valve<\/article>\n<article class=\"accordion-lang260px\">2. Niveau transmitter to control the boiler water normal level<\/article>\n<article class=\"accordion-lang260px\">3. Electrode for boiler water high level in self monitoring design<\/article>\n<article class=\"accordion-lang260px\">4.\/5. Electrodes for boiler water low level in self monitoring design<\/article>\n<article class=\"accordion-lang260px\">6. Safety valve<\/article>\n<article class=\"accordion-lang260px\">7. Vent valve<\/article>\n<article class=\"accordion-lang260px\">8. Level indicator<\/article>\n<article class=\"accordion-lang260px\">9. Flue gas temperature limiter<\/article>\n<article class=\"accordion-lang260px\">10. Steam pressure &#8211; gauge<\/article>\n<article class=\"accordion-lang260px\">11. Steam pressure transmitter to control the operating steam pressure<\/article>\n<article class=\"accordion-lang260px\">12. Steam pressure limiter<\/article>\n<article class=\"accordion-lang260px\">13. Electrode for monitoring the boiler water conductivity and control the boiler water blow down capacity<\/article>\n<article class=\"accordion-lang260px\">13a. Continuous boiler water blow down valve<\/article>\n<article class=\"accordion-lang260px\">14. Sample cooler<\/article>\n<article class=\"accordion-lang260px\">15. Feed water pump<\/article>\n<article class=\"accordion-lang260px\">15a. Stand-by feed water pump<\/article>\n<article class=\"accordion-lang260px\">16. Intermittent boiler water blow down valve for condensate header 1<\/article>\n<article class=\"accordion-lang260px\">16a. Intermittent boiler water blow down valve for condensate header 2<\/article>\n<article class=\"accordion-lang260px\">17. Manual blow down valve main Header<\/article>\n<article class=\"accordion-lang260px\">18. Cooling water<\/article>\n<article class=\"accordion-lang260px\">19. Feed water &#8211; inlet<\/article>\n<article class=\"accordion-lang260px\">20. Drain water<\/article>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p> You find further technical information on every type of boiler in the download area of our internet site.<\/article>\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>The basis for the High Pressure Steam Boiler in open steam\/condensate cycle The basis for the GekaKonus\u00ae High Pressure Steam Boiler in open steam\/condensate cycle type NWK-HP\u00a0system is a modified GekaKonus\u00ae Natural Circulation Steam Boiler type NUK-HP\u00ae combined with a steam drum. The GekaKonus\u00ae NWK-HP\u00a0system is being used in heating processes where the implementation of [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":27,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/gekakonus.net\/en\/wp-json\/wp\/v2\/pages\/209"}],"collection":[{"href":"https:\/\/gekakonus.net\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/gekakonus.net\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/gekakonus.net\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gekakonus.net\/en\/wp-json\/wp\/v2\/comments?post=209"}],"version-history":[{"count":4,"href":"https:\/\/gekakonus.net\/en\/wp-json\/wp\/v2\/pages\/209\/revisions"}],"predecessor-version":[{"id":1274,"href":"https:\/\/gekakonus.net\/en\/wp-json\/wp\/v2\/pages\/209\/revisions\/1274"}],"up":[{"embeddable":true,"href":"https:\/\/gekakonus.net\/en\/wp-json\/wp\/v2\/pages\/27"}],"wp:attachment":[{"href":"https:\/\/gekakonus.net\/en\/wp-json\/wp\/v2\/media?parent=209"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}