{"id":217,"date":"2016-11-28T11:14:27","date_gmt":"2016-11-28T11:14:27","guid":{"rendered":"http:\/\/wp.gekakonus.net\/?page_id=217"},"modified":"2017-04-27T15:10:05","modified_gmt":"2017-04-27T15:10:05","slug":"schnelldampferzeuger","status":"publish","type":"page","link":"https:\/\/gekakonus.net\/en\/produkte\/schnelldampferzeuger\/","title":{"rendered":"Quick Steam Generator"},"content":{"rendered":"<p><\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"size-full wp-image-220 aligncenter\" src=\"https:\/\/wp.gekakonus.net\/wp-content\/uploads\/2016\/11\/LSG-HP.jpg\" alt=\"lsg-hp\" width=\"500\" height=\"293\" srcset=\"https:\/\/gekakonus.net\/wp-content\/uploads\/2016\/11\/LSG-HP.jpg 500w, https:\/\/gekakonus.net\/wp-content\/uploads\/2016\/11\/LSG-HP-300x176.jpg 300w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/p>\n<h1>The quick steam generator LSG-HP<\/h1>\n<p>The LSG-HP quick steam generator is a once-through forced flow steam generator. The system consists of a continuous bended single pass through spiral tube system. The feed water is feed into the tube system by means of an accurate positive displacement pump(s). The GekaKonus\u00ae quick steam generator system type GekaKonus\u00ae LSG-HP is designed for an open steam\/condensate system.<\/p>\n<div>\n<h2>\u00a0<\/h2>\n<table class=\" alignleft\" style=\"border-color: #fa0202; background-color: #fc0303;\">\n<thead>\n<tr style=\"background-color: #f70505;\">\n<td><span style=\"font-family: arial,helvetica,sans-serif; font-size: 20px;\"><strong>Application\/Advantages<br \/>\n <\/strong><\/span><\/td>\n<\/tr>\n<\/thead>\n<\/table>\n<p>Application<br \/>\n The quick steam generator system GekaKonus\u00ae is being used where the implantation of a closed steam\/condensate cycle system in depends of the required process technology not possible. This is for example the case for heating processes where it is necessary to operate with different steam pressures at different stages in the production process within the same system e. g. with different saturated steam temperatures or in processes where the condensate is partial or total loss.<\/p>\n<p>GekaKonus GmbH\u00a0<\/p>\n<p>Advantages<\/p>\n<ul type=\"disc\">\n<li>LSG-HP designed for minimum water content and quickest possible service availability<\/li>\n<li>Small water content and low mass, combined with high heat transfer, enables full steam output and pressure to be raised in approximate 3-5 minutes from a start up<\/li>\n<li>The saturated steam escape mostly free from residue water and dissolved salts<\/li>\n<li>Instant saturated steam for process heating<\/li>\n<li>Steam temperature measurement and alarm means protection of the evaporator spiral tube system against overheating<\/li>\n<li>Measurement of the feed water inlet pressure on the feed water pump means protection against cavitations<\/li>\n<li>2- stage or modulating capacity control range<\/li>\n<li>We are also able to offer customized capacity ranges<\/li>\n<li>The system design guarantees free and easy access to the burner, instrumentation and facilities and good working condition for set up by commissioning and maintenance<\/li>\n<li>The combustion chamber doesn\u00b9t contain any refractory. Therefore no heat storage in the combustion chamber and no uncontrolled after-evaporation in case of a quick capacity and\/or an emergency shut down<\/li>\n<\/ul>\n<p>You find further technical information on every type of heater in the download area of our internet site.<\/p>\n<\/div>\n<table style=\"border-color: #f50521; background-color: #fa0522;\">\n<tbody>\n<tr>\n<td><strong><span style=\"font-family: arial,helvetica,sans-serif; font-size: 20px;\">Production\/Equipment<\/span><\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<article class=\"accordion-lang380px\"><\/article>\n<article class=\"accordion-lang380px\">\n<p>Production\/Equipment<br \/>\n The production process and the control and safety equipment comply with the rules of the European Community (PED 97\/23\/EC) and other notified bodies world wide(e. g. SELO, ASME, GOST-R, ROSTECHNADZOR), as far as this has been agreed. The quick steam generator equipment is designed acc, the PED 97\/23\/EC rules for 24-hour operation without supervision.<\/p>\n<p>Control<br \/>\n The capacity is controlled by pressure. Depend on the steam pressure, the burner capacity will be increased or reduced. The feed water pump and burner works in conjunction depends on the steam production rate.<\/p>\n<p>You find further technical information on every type of boiler in the download area of our internet site.<\/p>\n<p>Burner<br \/>\n The GekaKonus\u00ae LSG-HP system is suitable for operation with burner using high speed diesel, heavy fuel oil, natural gas, LPG, biogas and bio diesel or using a dual fuel burner.<br \/>\n Permanent Monitoring<\/p>\n<p> A permanent supervision of the following parameters<\/p>\n<p> \u00a0\u00a0\u00a0 Steam pressure &#8211; Operation<br \/>\n \u00a0\u00a0\u00a0 Steam pressure &#8211; maximum<br \/>\n \u00a0\u00a0\u00a0 Steam temperature &#8211; super heating<br \/>\n \u00a0\u00a0\u00a0 Feed water inlet temperature &#8211; minimum<br \/>\n \u00a0\u00a0\u00a0 Feed water inlet pressure &#8211; Feed water pump<br \/>\n \u00a0\u00a0\u00a0 Exhaust gas temperature &#8211; high<br \/>\n \u00a0\u00a0\u00a0 Residue water blow down &#8211; Permanent<br \/>\n \u00a0\u00a0\u00a0 Burner &#8211; Flame monitoring<\/p>\n<p> Continuous Blow Down<br \/>\n The blow down is obtained by a continuous process. Blow down of the quick steam generator is an absolute necessity to keep the access steam to the process heating system mostly free from residual moisture and dissolved salts.<\/p>\n<p> Automatic Shut Down<br \/>\n In the event of any primary component or service failure, the safety devices will shut-down the entire system and provide visual and audible alarms.<\/article>\n<article class=\"accordion-lang380px\"><\/article>\n<table style=\"border-color: #fa0000; background-color: #fa0000;\">\n<tbody>\n<tr>\n<td><strong><span style=\"font-family: arial,helvetica,sans-serif; font-size: 20px;\">Technical Data<\/span><\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div>\n<p>Capacity range<br \/>\n Up to 3.400 kW,<br \/>\n steam flow rate up to 3.500 kg\/h and<br \/>\n pressure range from 30 bar up to 95 bar design pressure.<\/p>\n<p>You find further technical information on every type of boiler in the download area of our internet site.<\/p>\n<\/div>\n<div>\u00a0<\/div>\n<table style=\"border-color: #fa0000; background-color: #fa0000;\">\n<tbody>\n<tr>\n<td><strong><span style=\"font-family: arial,helvetica,sans-serif; font-size: 20px;\">P + I DIAGRAMM UND SCHEMA<\/span><\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<article class=\"accordion-lang260px\"><span style=\"font-family: arial,helvetica,sans-serif;\"><span style=\"font-family: arial,helvetica,sans-serif;\"><span style=\"font-family: arial,helvetica,sans-serif;\"><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/www.gekakonus.net\/web2016c\/bilder\/space.gif\" alt=\"\" width=\"20\" height=\"1\" border=\"0\" \/><a href=\"https:\/\/wp.gekakonus.net\/wp-content\/uploads\/2016\/11\/diagramm_lsg1g.png\"><img decoding=\"async\" loading=\"lazy\" class=\"alignleft wp-image-226 size-thumbnail\" src=\"https:\/\/wp.gekakonus.net\/wp-content\/uploads\/2016\/11\/diagramm_lsg1g-150x150.png\" width=\"150\" height=\"150\" \/><\/a><\/span><\/span><\/span><span style=\"font-family: arial,helvetica,sans-serif;\"><span style=\"font-family: arial,helvetica,sans-serif;\"><br \/>\n <\/span><\/span><\/p>\n<table style=\"width: 599.33px;\">\n<tbody>\n<tr>\n<td style=\"width: 590.33px;\">\n<p>6. Safety temperature limiter &#8211; flue gas and indication<br \/>\n 8. Pressure safety limiter &#8211; steam<br \/>\n 9. Pressure controller &#8211; steam<br \/>\n 10a. Temperature limiter &#8211; steam and indication<br \/>\n 10b. Temperature limiter &#8211; steam and indication<br \/>\n 12. Pressure gauge &#8211; steam<br \/>\n 13. Valve<br \/>\n 14. Temperature indication &#8211; feed water<br \/>\n 15. Pressure gauge &#8211; feed water<br \/>\n 16a. Feed water pump<br \/>\n 16b. Stand-by feed water pump<br \/>\n 17. Drain valve<br \/>\n 18. Steam trap<br \/>\n 19. Steam separator<br \/>\n 20. Sight glass<br \/>\n 21. Pressure switch &#8211; low pressure feed water<br \/>\n 22. Valve on\/off steam<br \/>\n 23. Safety valve &#8211; steam pressure<br \/>\n 24. Safety valve &#8211; feed water pressure<br \/>\n 25. Non return valve<br \/>\n 26. Valve feed water<br \/>\n 26a. Valve feed water<br \/>\n 26b. Valve feed water<br \/>\n 27a. Strainer &#8211; feed water<br \/>\n 27b. Strainer &#8211; feed water<br \/>\n 28a. Valve feed water<br \/>\n 28b. Valve feed water<br \/>\n 33. Steam &#8211; outlet<br \/>\n 34. Feed water &#8211; inlet<br \/>\n 35. Drain water<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-family: arial,helvetica,sans-serif;\"><br \/>\n <\/span>You find further technical information on every type of boiler in the download area of our internet site.<\/article>\n<article class=\"accordion-lang260px\"><\/article>\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>The quick steam generator LSG-HP The LSG-HP quick steam generator is a once-through forced flow steam generator. The system consists of a continuous bended single pass through spiral tube system. The feed water is feed into the tube system by means of an accurate positive displacement pump(s). The GekaKonus\u00ae quick steam generator system type GekaKonus\u00ae [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":27,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/gekakonus.net\/en\/wp-json\/wp\/v2\/pages\/217"}],"collection":[{"href":"https:\/\/gekakonus.net\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/gekakonus.net\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/gekakonus.net\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gekakonus.net\/en\/wp-json\/wp\/v2\/comments?post=217"}],"version-history":[{"count":7,"href":"https:\/\/gekakonus.net\/en\/wp-json\/wp\/v2\/pages\/217\/revisions"}],"predecessor-version":[{"id":1320,"href":"https:\/\/gekakonus.net\/en\/wp-json\/wp\/v2\/pages\/217\/revisions\/1320"}],"up":[{"embeddable":true,"href":"https:\/\/gekakonus.net\/en\/wp-json\/wp\/v2\/pages\/27"}],"wp:attachment":[{"href":"https:\/\/gekakonus.net\/en\/wp-json\/wp\/v2\/media?parent=217"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}